ISO & POLYOL X-8580DX Sewer polyurea COATING

X-8580DX revolutionizes sewer and wastewater infrastructure protection with its thermally sprayed, rapid-cure polyurea technology. Engineered for direct application on damp concrete/metal surfaces, this two-component coating forms an impervious barrier against moisture, chemical corrosion, and mechanical stress. With a lightning-fast 30-second tack-free time and unmatched adhesion, it minimizes downtime in critical maintenance projects.

Key Features

Wet-Substrate Application Sprays directly onto moist concrete/metal (mines, manholes, pipelines) without surface drying. Eliminates project delays from weather or groundwater.

Ultra-Rapid Cure Performance

  • Gel time: 5-10 seconds | Tack-free: 30 seconds (25°C, 50% RH)
  • Walkable surface in <1 minute, accelerates project timelines

Extreme Environment Durability

  • Temperature range: -45°C to 100°C (maintains flexibility in freezing sewers)
  • Tensile strength: >50 MPa | Hardness: Shore D 80
  • Water absorption: <2% after 7-day immersion

Eco-Efficient Formulation

  • Solids content: ≥98% (low-VOC, compliant with HJ 457-2009)
  • Coverage: 1kg/m²/mm thickness (20% over-spray factored)

The X-8580DX polyurea coating is Ideal for critical infrastructure protection::

🔹 Sewer lines & manhole rehabilitation

🔹 Underground pipe galleries & basement waterproofing

🔹 Corrosion protection in wastewater pipelines

🔹 Mining infrastructure & concrete repair

Technical Parameters

PropertyValue
Gel Time5-10 sec
Tensile Strength>50 MPa
Hardness (Shore D)80
Use Temperature-45°C to 100°C
Water Absorption<2% (7-day soak)
Packaging50L pails / 209L drums
Shelf Life12 months

Application Guidelines

  1. Surface Prep: Clean substrates; repair major voids. Light moisture acceptable.
  2. Mixing: Blend Components A/B (240kg:210kg/drum) mechanically. Maintain uniformity.
  3. Spray Parameters:
    • Ambient Temp: 5°C–35°C
    • Equipment: Heated plural-component spray rig
    • Film Thickness: Adjust per project (standard DFT: 1.5-2mm)
  4. QC Protocol: Inspect for pinholes/bubbles; recoat defects within 48h.
  5. Safety: Wear NIOSH masks, goggles, gloves. Ventilate enclosed spaces.

Application

Application Guidelines

  1. Surface Prep: Clean substrates; repair major voids. Light moisture acceptable.
  2. Mixing: Blend Components A/B (240kg:210kg/drum) mechanically. Maintain uniformity.
  3. Spray Parameters:
    • Ambient Temp: 5°C–35°C
    • Equipment: Heated plural-component spray rig
    • Film Thickness: Adjust per project (standard DFT: 1.5-2mm)
  4. QC Protocol: Inspect for pinholes/bubbles; recoat defects within 48h.
  5. Safety: Wear NIOSH masks, goggles, gloves. Ventilate enclosed spaces.

This website is Using cookies.

We use them to give you the best experience, If you continue using our website, we’ll assume that you are happy to receive all cookies on this website.